Fluid Mechanics Lab Equipment

Manufacturer & Exporter of a wide range of products which include Fluid Mechanics Lab Equipment such as Bernoulli's Theorem Apparatus, Impact Of Jet On Vanes Apparatus, Orifice & Mouthpiece Apparatus, Study Of Pipe Fittings, Reynold's Apparatus and Venturimeter & Orificemeter Apparatus.
Bernoulli's Theorem Apparatus

Bernoulli's Theorem Apparatus



The setup is designed to verify Bernoulli's Theorem experimentally

 

Set up consists of a one piece clear acrylic test section with convergent and divergent part sections, supply thank, measuring tank, inlet water tank and pump for closed loop water circulation. The test section is connected to Piezometer Tubes through pressure tapping at different locations on the section to demonstrate the Bernoulli’s Theorem.

 

The flow rate of water is measured using measuring tank and stop watch provided.



Send Enquiry



Impact Of Jet On Vanes Apparatus



The setup is designed to study the forced developed by a jet of water on different surfaces and to compare it with momentum theory.

Set up consists of visible test enclosure, supply tank, measuring tank and pump for closed loop water circulation. The visible test section housed one nozzle fitted in vertical upward direction to target the jet of water opposite an interchangeable test surface (either flat plate or a hemispherical cup) which in term is connected to a spring loaded stem. The lift of stem and weight added to the pan on other side gives the calculation of corresponding force.

 

The flow rate of water is measured using measuring tank and stop watch provided.



Impact Of Jet On Vanes Apparatus

Send Enquiry



Orifice & Mouthpiece Apparatus

Orifice & Mouthpiece Apparatus



The setup is designed to study the discharge through different orifice & mouthpiece.

 

Set up consists of an adjustable head constant level tank, supply tank, measuring tank and pump for closed loop water circulation. The constant level tank is fitted with arrangement for creating jet using different interchangeable orifice and mouthpiece. A hook/pointer gauge for measuring x-y coordinates of jet is also fitted.

 

The flow rate of water is measured using measuring tank and stop watch provided.

 



Send Enquiry



Study Of Pipe Fittings



The set up consists of a 1/2 bend and elbow, a sudden expansion & sudden contraction fitting from 15mm to 25mm, ball valve and gate valve. Pressure tapings are provided at inlet and outlet of these fittings under test. A differential manometer fitted in the line gives pressure loss of individual fittings. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.

 



Study Of Pipe Fittings

Send Enquiry



Reynold's Apparatus

Reynold's Apparatus



The apparatus consists of a glass tube with one end having bell mouth entrance; connected to a constant head water tank, at the other end a valve is provided to vary the flow rate. The tank is of sufficient capacity to store water; a capillary tube is introduced centrally in the bell mouth for feeding dye from a small container placed at the top of tank, through polythene tubing. By varying the rate of flow, the reynolds number is changed; this also changes the type of flow. Visual observation of dye (thread) will indicate the type of flow, which can be confirmed from the reynolds number computed. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line. Flow rate of water is measured with the help of measuring cylinder and stop watch.

Send Enquiry



Venturimeter & Orificemeter Apparatus



The apparatus consists of two pipelines emerging out from a common manifold. One pipeline contain a Venturimeter and other contain an Orifice. The pressure tapings from the Venturimeter and Orificemeter are taken to differential manometer to measure pressure difference. The Venturimeter & Orificemeter are connected in parallel and anyone of them can be put in operation by operating valves provided at the downstream. These valves can also regulate the flow.

Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stopwatch.



Venturimeter & Orificemeter Apparatus

Send Enquiry







Contact us

Mr. Varun Chopra (CEO)
Edutek House, 29- B, Inderpuri, Ambala Cantt
Ambala, Haryana - 133 001, India
Telephone:  +(91)-(171)-2654329



Home  |   About Us  |  Our Products   |   Media Gallery  |  Site Map  |   Contact Us   |  Enquiry

Member IndiaMART.com © Edutek Instrumentation. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry