EOTL-149. 46this hydraulic operation table has been made using superb craftmanship and using prime quality raw materials confirming to latest ammendments updated. This sturdily built operation table is suitable for all major and minor operating procedures e. G. General surgery, gynaecology - obstetrics, urology, cardio thoracis, opthalmic etc. It is supplied with the following standard accessories :• s. S. Arm rest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 no. • anaesthetic screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 no. • lithotomy leg holders with stirr-ups . . . . . . . . . . . . . . . 1 set• leather wristlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 set Padded leg rest (gutter type) can be supplied at an extra cost. The table will attain the following positions :• trendelenberg• reverse trendelenberg• lateral on either sides• flex• reflex• chair It will have the following salient features :• detachable head rest is easily adjustable to any desired position, above or below table top. • detachable leg section facilitates ortho-attachment to be assembled at later stage. It is also most convenient to gynaecologist & urologist• table top can be rotated 360° through base• kidney bridge is provided to attain 13 cms height. • all corners of base and table top are rounded to avoid any injury |
EOTL-149. 57dimensionsadome head :715mm dia. Halogen bulbs :7nos. 12v x 50 wattlight intensity at 1 mt. :1,20,000 luxintensity control :4 stageheight adjustment :500mmaction radius :1850mmpossible movements :radial, angular & axialcolour temperature :4200 k ± 300ktemp. Rise in field :4° - 8° c from amb. Templow voltage unitwith cvt :1 no. (c. V. T optional)input supply voltage :22ovolta. C± 10% 50hz ± 2% bdome head :515mm dia. Halogen bulbs :4nos. 12v x 50 wattlight intensity at 1 mt. :70,000 luxintensity control :4 stageheight adjustment :550mmaction radius :1550mmpossible movements :radial, angular & axialcolour temperature :4200 k ± 300ktemp. Rise in field :3°-6° c from amb. Templow voltage unitwith cvt :1 no. (C. V. T optional)input supply voltage :22ovolt a. C ± 10% |
|
|
EOTL-149. 58dimensions adome head :515mm dia. Halogen bulbs :4nos. 12v x 50 wattlight intensity at 1 mt. :70,000 luxintensity control :4 stageheight adjustment :600mmaction radius :1850mmpossible movements :radial, angular & axialcolour temperature :4200 k ± 300ktemp. Rise in field :3°-6° c from amb. Templow voltage unitwith cvt :1 no. (C. V. T optional)input supply voltage :22ovolt A. C ± 10phz ± 2% bdome head :515mm dia. Halogen bulbs :4nos. 12v x 50 wattlight intensity at 1 mt. :70,000 luxintensity control :4 stageheight adjustment :550mmaction radius :1550mmpossible movements :radial, angular & axialcolour temperature :4200 k ± 300ktemp. Rise in field :3°-6° c from amb. Templow voltage unitwith CVT :1 no. (C. V. T optional)input supply voltage :22ovolt A. C ± 10% 50hz ± 2% |
EOTL-149. 59 dimensions dome head :715mm dia. Halogen bulbs :7nos. 12v x 50 watt light intensity at 1 mt. :1,20,000 lux intensity control :4 stage height adjustment :500mmaction radius :1850mmpossible movements :radial, angular & axial colour temperature :4200 k ± 300ktemp. Rise in field :3° - 6° c from amb. Templow voltage unitwith cvt :1 no. (c. V. T optional)input supply voltage :22ovolta. C± 10% 50hz ± 2%. |
|
|
EOTL-149.60 Dimensions Dome Head :515mm Dia. Halogen Bulbs :4nos. 12v x 50 watt Light intensity at 1 mt. :70,000 Lux Intensity Control :4 Stage Height Adjustment :550 mm Action Radius :1550mm Possible Movements :Radial Angular & Axial Colour Temperature :4200 K ± 300KTemp. Rise in field :3°-6° c from Amb. Temp Low voltage unit with CVT :1 No. (C.V.T optional) Input Supply Voltage :22Ovolt A.C ± 10% 50Hz ± 2%. |
EOTL-149. 61dimensions dome head :515mm dia. Halogen bulbs :4nos. 12v x 50 wattlight intensity at 1 mt. :70,000 luxintensity control :4 stageheight adjustment :600 mm approx. Action radius :1250mmpossible movements :radial, angular & axialcolour temperature :4200 k ± 300ktemp. Rise in field :3°-6° c from amb. Templow voltage unitwith cvt :1 no. (C. V. T optional)input supply voltage :22ovolt a. C ± 10% 50hz ± 2% |
|
|
ECLS-149. 82technical specifications: model :single lamp / double lampoutput power :250 watts (24 volts)input :180 vac - 270 VAC features:-• S. M. P. S. Based design ensures smooth working of light source within the voltage variation of 180 -270 VAC. • half the weight & size of the conventional light sources. • light intensity controlled with smooth rotary potentiometer• competitive rates, efficient service backup of india. |
EOTF-149. 83these ot fumigators consume negligible power and virtuallyrequire no maintenance. Provides operation theater fumigatorto suit the requirements of each and every medical profession. These operation theater fumigator are used in most of theindian hospitals and dispensaries operation theatre(ot) fumigator Technical data:body : fully stainless steelmaximum height : 16 inchesouter diameter : 17 inches. Weight : 9 kgs (appr. )electric supply : 230 50hz. Single phase a. C. Connected load : 90 wattspower consumption : 0. 150kws / hr. Atomizing cap. : 30 - 35 ml / min features:-• light weight and portable• easy to operate virtually no maintenance required. • negligible power consumption. • 100% convenient disinfection procedure• unpack the equipment and check the functioning by plugging it into a pin 5 amps 230 v electrical socket• ascertain the dos'age required for the room to be disinfected. • place 'ot fumigator' inside the operation theatre. • pour in the formation & water into the dish from sides. • close and seal all the windows, ventilators openings and the door of the place to be disinfected. • plug in the unit's main cord into a 3 pin, 5 amp, 230v, electrical sockets with switch. Which must be provided outside the operation theatre or use automatic timer. • switch on the 'ot fumigator' and allow it to run for 30 minutes then switch it off. • wait for 6 hours and open the room before re-using the room, exhaust remaining fumes if any by switching on the fan / exhaust of the window and airconditioner. |
|